906 Fabric OS Message Reference
53-1003140-01
SULB-1050
5
SULB-1050
Message Firmwaredownload command continues.
Message Type AUDIT | LOG
Class FIRMWARE
Severity INFO
Probable Cause Indicates that the firmwareDownload command is running on the standby control processor (CP) of the
dual-CP system. This process should take approximately 17 minutes. The process is set to time out after
30 minutes.
Recommended
Action
Do not fail over or power down the system during firmware upgrade. Allow the firmwareDownload
command to continue without disruption. No action is required.
Run the firmwareDownloadStatus command for more information.
SULB-1051
Message Detected hot-plug of Standby CP. Firmware from Active CP will automatically be
synchronized to Standby CP.
Message Type AUDIT | LOG
Class FIRMWARE
Severity INFO
Probable Cause Indicates that auto firmware synchronization has started because the standby control processor (CP) is
hot-plugged.
Recommended
Action
No action is required. Firmware download has started on the standby CP.
SULB-1052
Message Firmwaresync has failed.<return code>
Message Type AUDIT | LOG
Class FIRMWARE
Severity ERROR
Probable Cause Indicated that auto firmware synchronization has failed.
Recommended
Action
Execute the firmwareDownloadStatus and firmwareShow commands to view firmware status.
Execute the haShow command to view the HA state.