Reference (Supporting Fabric OS v7.3.0) Owner manual

960 Fabric OS Message Reference
53-1003140-01
XTUN-4127
5
XTUN-4127
Message FTNL Tunnel <VE Port Number>.<Tunnel Group Number> (<Tunnel Id>) Circuit <Circuit
Number> <Priority Class>-Pri QoS DOWN (<Reason>).
Message Type LOG
Severity ERROR
Probable Cause Indicates that the specified circuit has gone down unexpectedly, and the tunnel will also be down if this is
the last circuit available.
Recommended
Action
If the tunnel or circuit has not been administratively disabled or deleted, a possible network error or
disruption has occurred.
XTUN-4137
Message FTNL Tunnel <VE Port Number>.<Tunnel Group Number> (<Tunnel Id>) Circuit <Circuit
Number> <Priority Class>-Pri QoS DOWN (<Reason>).
Message Type LOG
Severity INFO
Probable Cause Indicates that the specified circuit has gone down. The tunnel group is non-active or this is expected. The
tunnel will also be down if this is the last circuit available.
Recommended
Action
If the tunnel or circuit has not been administratively disabled or deleted, a possible network error or
disruption has occurred.