Manual

To display all the scheduler profiles configured in the runtime configuration for the system, use the
show scheduler-profileall command.
FCX and ICX 6450 platforms
The following tables show the default values for the scheduling type for stacking and stand-alone FCX
and ICX 6450 platforms.
Default values for scheduling type for stacking systems (for FCX and ICX 6450 platforms). TABLE 13
Traffic Class SP SP Jumbo WRR WRR Jumbo Mixed Mixed Jumbo
TC0 SP SP 3 8 15 15
TC1 SP SP 3 8 15 15
TC2 SP SP 3 8 15 15
TC3 SP SP 3 8 15 15
TC4 SP SP 3 8 15 15
TC5 SP SP 10 16 25 25
TC6 SP SP 75 44 SP SP
TC7 SP SP SP SP SP SP
Default values for scheduling type for stand-alone systems (for FCX and ICX 6450
platforms).
TABLE 14
SP SP Jumbo WRR WRR Jumbo Mixed Mixed Jumbo
TC0 SP SP 3 8 15 15
TC1 SP SP 3 8 15 15
TC2 SP SP 3 8 15 15
TC3 SP SP 3 8 15 15
TC4 SP SP 3 8 15 15
TC5 SP SP 3 8 25 25
TC6 SP SP 7 8 SP SP
TC7 SP SP 75 44 SP SP
Quality of Service
FastIron Ethernet Switch Traffic Management Guide 25
53-1003093-03