Software Upgrade Guide Manual

show command output differences between 07.4.00 and 08.0.xx
show ip
interface
loopback 2
Brocade#show ip interface loopback 1
Interface Loopback 1
port enabled
port state: UP
ip address: 1.0.0.1 subnet mask: 255.255.255.255
Port belongs to VRF: default-vrf
encapsulation: ETHERNET, mtu: 1500, metric: 1
directed-broadcast-forwarding: disabled
proxy-arp: disabled
ip arp-age: 10 minutes
No Helper Addresses are configured.
No inbound ip access-list is set
No outgoing ip access-list is set
VRF information is
added.
show ip
interface
tunnel 2
Brocade#show ip interface tunnel 2
Interface Tunnel 2
port enabled
port state: UP
ip address: 1.111.1.1 subnet mask: 255.255.255.252
Port belongs to VRF: default-vrf
encapsulation: GRE, mtu: 1476, metric: 1
directed-broadcast-forwarding: disabled
proxy-arp: disabled
ip arp-age: 10 minutes
No Helper Addresses are configured.
No inbound ip access-list is set
No outgoing ip access-list is set
VRF information is
added.
show ip
interface
ve 2
Brocade#show ip interface ve 100
Interface Ve 100
members: ethe 1/1/1
active: ethe 1/1/1
port enabled
port state: UP
ip address: 1.1.1.1 subnet mask: 255.255.255.252
Port belongs to VRF: default-vrf
encapsulation: ETHERNET, mtu: 1500, metric: 1
directed-broadcast-forwarding: disabled
proxy-arp: disabled
ip arp-age: 10 minutes
No Helper Addresses are configured.
No inbound ip access-list is set
No outgoing ip access-list is set
VRF information is
added.
show ip
tcp status
1.2.3.4 2
1.2.3.4 2
Brocade#show ip tcp status 1.0.0.1 179 1.0.0.2 8132
TCP: TCB = 0x24dcee60
TCP: 1.0.0.1:179 <-> 1.0.0.2:8132: state: ESTABLISHED VRF: 0
Send: initial sequence number = 2676825448
Send: first unacknowledged sequence number = 2676826779
Send: current send pointer = 2676826779
Send: next sequence number to send = 2676826779
Send: remote received window = 16384
Send: total unacknowledged sequence number = 0
Send: total used buffers 0
Receive: initial incoming sequence number = 725765880
Receive: expected incoming sequence number = 725767021
Receive: received window = 16384
Receive: bytes in receive queue = 0
Receive: congestion window = 1455
VRF information is
added.
FastIron Ethernet Switch Software Upgrade Guide
53-1003089-01