Configuration Guide User guide

76 FastIron Configuration Guide
53-1002494-02
Image file types
Brocade#verify md5 secondary 01c410d6d153189a4a5d36c955653861
Brocade#.........................Done
Size = 2044830, MD5 01c410d6d153189a4a5d36c955653862
Verification FAILED.
In the previous example, the codes did not match, and verification failed. If verification succeeds,
the output will look like this.
Brocade#verify md5 secondary 01c410d6d153189a4a5d36c955653861
Brocade#.........................Done
Size = 2044830, MD5 01c410d6d153189a4a5d36c955653861
Verification SUCEEDED.
The following examples show this process for SHA-1 and CRC32 algorithms.
Brocade#verify sha secondary 49d12d26552072337f7f5fcaef4cf4b742a9f525
Brocade#.........................Done
Size = 2044830, sha 49d12d26552072337f7f5fcaef4cf4b742a9f525
Verification SUCCEEDED.
and
Brocade#verify crc32 secondary b31fcbc0
Brocade#.........................Done
Size = 2044830, CRC32 b31fcbc0
Verification SUCCEEDED.
Image file types
This section lists the boot and flash image file types supported and how to install them on the
FastIron family of switches. For information about a specific version of code, refer to the release
notes.
TABLE 17 Software image files
Product Boot image
1
1. These images are applicable to these devices only and are not interchangeable. For example, you cannot
load FCX boot or flash images on a FSX device, and vice versa.
Flash image
FESX
FSX 800
FSX 1600
sxzxxxxx.bin SXSxxxxx.bin (Layer 2) or
SXLxxxxx.bin (base Layer 3) or
SXRxxxxx.bin (full Layer 3)
FWS fgzxxxxx.bin FGSxxxxx.bin (Layer 2) or
FGSLxxxxx.bin (base Layer 3) or
FGSRxxxxx.bin (edge Layer 3)
FCX
ICX 6610
grzxxxxxx.bin FCXSxxxxx.bin (Layer 2) or
FCXRxxxxx.bin (Layer 3)
ICX 6430
ICX 6450
kxz07400.bin ICX64S07400.bin (Layer 2) or
ICX64R07400.bin (Layer 3 - ICX
6450 only)