Configuration Guide User guide
FastIron Configuration Guide 1997
53-1002494-02
Syslog messages
Alert Power supply <num>, <location>, failed A power supply has failed.
The <num> is the power supply number.
The <location> describes where the failed
power supply is in the chassis.
Alert System: Module in slot <slot-num>
encountered PCI config read error: Bus
<PCI-bus-number>, Dev
<PCI-device-number>, Reg Offset
<PCI-config-register-offset>.
The module encountered a hardware
configuration read error.
Alert System: Module in slot <slot-num>
encountered PCI config write error: Bus
<PCI-bus-number>, Dev
<PCI-device-number>, Reg Offset
<PCI-config-register-offset>.
The module encountered a hardware
configuration write error.
Alert System: Module in slot <slot-num>
encountered PCI memory read error: Mem
Addr <memory-address>
The module encountered a hardware
memory read error.
The <memory-address> is in hexadecimal
format.
Alert System: Module in slot <slot-num>
encountered PCI memory write error: Mem
Addr <memory-address>.
The module encountered a hardware
memory write error.
The <memory-address> is in hexadecimal
format.
Alert System: Module in slot <slot-num>
encountered unrecoverable PCI bridge
validation failure. Module will be deleted.
The module encountered an unrecoverable
(hardware) bridge validation failure. The
module will be disabled or powered down.
Alert System: Module in slot <slot-num>
encountered unrecoverable PCI config read
failure. Module will be deleted.
The module encountered an unrecoverable
hardware configuration read failure. The
module will be disabled or powered down.
Alert System: Module in slot <slot-num>
encountered unrecoverable PCI config write
failure. Module will be deleted.
The module encountered an unrecoverable
hardware configuration write failure. The
module will be disabled or powered down.
Alert System: Module in slot <slot-num>
encountered unrecoverable PCI device
validation failure. Module will be deleted.
The module encountered an unrecoverable
(hardware) device validation failure. The
module will be disabled or powered down.
Alert System: Module in slot <slot-num>
encountered unrecoverable PCI memory
read failure. Module will be deleted.
The module encountered an unrecoverable
hardware memory read failure. The module
will be disabled or powered down.
Alert System: Module in slot <slot-num>
encountered unrecoverable PCI memory
write failure. Module will be deleted.
The module encountered an unrecoverable
hardware memory write failure. The module
will be disabled or powered down.
Alert System: No Free Tcam Entry available.
System will be unstable
In FWS devices, the limit for the TCAM
routing entries has been reached. You must
reboot the device.
Alert System: Temperature is over shutdown level,
system is going to be reset in <num>
seconds
The chassis temperature has risen above
shutdown level. The system will be shut
down in the amount of time indicated.
TABLE 1 Brocade Syslog messages (Continued)
Message level Message Explanation