Configuration Guide User guide

276 FastIron Configuration Guide
53-1002494-02
Brocade IronStack management
To configure a stack MAC address manually, enter the following command.
Brocade(config)# stack mac 0000.0000.0011
Syntax: [no] stack mac <mac-address>
The <mac-address> variable is a hexadecimal MAC address in the xxxx.xxxx.xxxx format.
Enter the no form of this command to return the MAC address to that of the Active Controller.
Output for this command resembles the following.
Brocade(config)# stack mac 0000.0000.0011
Brocade(config)# show running-config
Current configuration:
!
ver 05.0.01 100T7e1
!
stack 1
module 1 fcx-48-port-copper-base-module
module 2 fcx-cx4-1-port-10g-module
priority 80
stack 2
module 1 fcx-24-port-copper-base-module
module 2 fcx-cx4-1-port-10g-module
module 3 fcx-cx4-1-port-10g-module
stack enable
stack mac 0000.0000.0011
To display the stack MAC address, enter the show chassis command.
Brocade# show chassis
The stack unit 1 chassis info:
Power supply 1 (NA - AC - Regular) present, status ok
Power supply 2 not present
Fan 1 ok
Fan 2 ok
Exhaust Side Temperature Readings:
Current temperature : 35.5 deg-C
Warning level.......: 80.0 deg-C
Shutdown level......: 90.0 deg-C
Intake Side Temperature Readings:
Current temperature : 33.5 deg-C
Boot Prom MAC: 0012.f2de.9440
Management MAC: 0000.0000.0011
The stack unit 2 chassis info:
Power supply 1 (NA - AC - Regular) present, status ok
Power supply 2 not present
Fan 1 ok
Fan 2 ok
--More--, next page: Space, next line: Return key, quit: Control-c