Configuration Guide User guide

502 FastIron Configuration Guide
53-1002494-02
Digital optical monitoring
Vendor: Brocade Communications, Inc. Version: A
Part# : FTLF1323P1BTR-FD Serial#: UCT000T
Port 1/8: Type : EMPTY
Port 1/9: Type : 100M M-FX-LR(SFP)
Vendor: Brocade Communications, Inc. Version: A
Part# : FTLF1323P1BTL-FD Serial#: UD3085J
Port 1/10: Type : EMPTY
Port 1/11: Type : 100M M-FX-SR(SFP)
Vendor: Brocade Communications, Inc. Version: A
Part# : FTLF1217P2BTL-F1 Serial#: UCQ003J
Port 1/12: Type : EMPTY
Port 1/13: Type : 100M M-FX-IR(SFP)
Vendor: Brocade Communications, Inc. Version: A
Part# : FTLF1323P1BTR-F1 Serial#: PCA2XC5
Use the show media ethernet command to obtain information about the media device installed in a
port.
Brocade#show media e 1/17
Port 1/17: Type : 1G M-SX(SFP)
Vendor: Brocade Communications, Inc. Version:
Part# : PL-XPL-VC-S13-19 Serial#: 425HC109
Syntax: show media [slot <slot-num> | ethernet [<slot-num>/]<port-num>]
Viewing optical monitoring information
You can view temperature and power information for qualified XFPs, SFPs, and SFP+ installed in a
FastIron device.
Use the show optic <port-number> command to view information about an XFP, SFP, or SFP+
installed in a particular port. The following shows example output.
Optical monitoring feature will not work in the following scenarios:
The port is DOWN.
The port is configured as a stacking port.
The the optic module does not support optical monitoring.
For ICX 6430 devices only:
- If an SFP+ optic is inserted in an SFP only port, the optic will not initialize.
- If an SFP optic is inserted in an SFP+ only port, the optic will not initialize.
- If an optic is inserted into a device that supports both SFP and SFP+ optics, use the
speed-duplex command to set the port speed correctly.
Brocade#show optic 13
Port Temperature Tx Power Rx Power Tx Bias Current
+----+-----------+----------+------------+-------------------+
13 33.2968 C -005.4075 dBm -007.4328 dBm 6.306 mA
Normal Normal Normal Normal
Syntax: show optic <port-number>