Digital optical monitoring
Viewing optical transceiver thresholds
The thresholds that determine the alarm status values for an optical transceiver are set by the
manufacturer of the XFP, SFP, or SFP+. To view the thresholds for a qualified optical transceiver in
a particular port, use the show optic threshold command as shown below.
Syntax: show optic threshold <port>
Specify the port variable in one of the following formats:
• FWS, FCX, and ICX stackable switches – stack-unit/slotnum/portnum
• FSX 800 and FSX 1600 chassis devices – slotnum/portnum
• ICX devices – slotnum/portnum
• FESX compact switches – portnum
TABLE 91 Alarm status value description
Status value Description
Low-Alarm Monitored level has dropped below the "low-alarm" threshold set by the manufacturer of the
optical transceiver.
Low-Warn Monitored level has dropped below the "low-warn" threshold set by the manufacturer of the
optical transceiver.
Normal Monitored level is within the "normal" range set by the manufacturer of the optical transceiver.
High-Warn Monitored level has climbed above the "high-warn" threshold set by the manufacturer of the
optical transceiver.
High-Alarm Monitored level has climbed above the "high-alarm" threshold set by the manufacturer of the
optical transceiver.
Brocade>show optic threshold 2/2
Port 2/2 sfp monitor thresholds:
Temperature High alarm 5a00 90.0000 C
Temperature Low alarm d300 -45.0000 C
Temperature High warning 5500 85.0000 C
Temperature Low warning d800 -40.0000 C
Supply Voltage High alarm 9088
Supply Voltage Low alarm 7148
Supply Voltage High warning 8ca0
Supply Voltage Low warning 7530
TX Bias High alarm 7530 60.000 mA
TX Bias Low alarm 01f4 1.000 mA
TX Bias High warning 61a8 50.000 mA
TX Bias Low warning 05dc 3.000 mA
TX Power High alarm 1f07 -001.0001 dBm
TX Power Low alarm 02c4 -011.4996 dBm
TX Power High warning 18a6 -001.9997 dBm
TX Power Low warning 037b -010.5012 dBm
RX Power High alarm 2710 000.0000 dBm
RX Power Low alarm 0028 -023.9794 dBm
RX Power High warning 1f07 -001.0001 dBm
RX Power Low warning 0032 -023.0102 dBm