Configuration Guide User guide
668 FastIron Configuration Guide
53-1002494-02
Power over Ethernet overview
PoE Info: FW Download on slot 1 module 1...(re)sending download command...
PoE Info: FW Download on slot 1 module 1...TPE response received.
PoE Info: FW Download on slot 1 module 1...(re)sending erase command...
PoE Info: FW Download on slot 1 module 1...erase command...accepted.
PoE Info: FW Download on slot 1 module 1...erasing firmware memory...
PoE Info: FW Download on slot 1 module 1...erasing firmware memory...completed
PoE Info: FW Download on slot 1 module 1...(re)sending program command...
PoE Info: FW Download on slot 1 module 1...sending program command...accepted.
PoE Info: FW Download on slot 1 module 1...programming firmware...takes ~ 10
minutes....
PoE Info: Firmware Download on slot 1.....10 percent completed.
PoE Info: Firmware Download on slot 1.....20 percent completed.
PoE Info: Firmware Download on slot 1.....30 percent completed.
PoE Info: Firmware Download on slot 1.....40 percent completed.
PoE Info: Firmware Download on slot 1.....50 percent completed.
PoE Info: Firmware Download on slot 1.....60 percent completed.
PoE Info: Firmware Download on slot 1.....70 percent completed.
PoE Info: Firmware Download on slot 1.....80 percent completed.
PoE Info: Firmware Download on slot 1.....90 percent completed.
PoE Info: Firmware Download on slot 1.....100 percent completed.
PoE Info: FW Download on slot 1 module 1...programming firmware...completed.
3. After downloading the firmware into the controller, the controller resets and reboot with the
new PoE firmware, You should see output similar to the following.
PoE Info: FW Download on slot 1 module 1...upgrading firmware...completed.
Module will be reset.
PoE Info: Resetting module 1 in slot 1....
PoE Info: Resetting module 1 in slot 1....completed.
PoE Info: Programming Brocade defaults on module 1 in slot 1.....
PoE Info: Programming Brocade defaults. Step 1: Writing port defaults on
module 1 in slot 1....
PoE Info: Programming Brocade Defaults: Step 2: Writing PM defaults on module
1 in slot 1.
PoE Info: Programming Brocade defaults. Step 3: Writing user byte 0xf0 on
module 1 in slot 1.
PoE Info: Programming Brocade defaults. Step 4: Saving settings on module 1 in
slot 1.
PoE Info: Programming Brocade defaults on module 1 in slot 1.....completed.
NOTE
If you are attempting to transfer a file using TFTP but have received an error message, refer to
“Diagnostic error codes and remedies for TFTP transfers” on page 93.
PoE and CPU utilization
Depending on the number of PoE-configured ports that have powered power devices, there may be
a slight and noticeable increase of up to 15 percent in CPU utilization. In typical scenarios, this is
normal behavior for PoE and does not affect the functionality of other features on the switch.