Reference Guide (Supporting software release 5.5.0.0 and later) Owner manual
Brocade Mobility Access Point System Reference Guide 469
53-1003100-01
6
FIGURE 34 SMART RF - Scanning Configuration screen
NOTE
The monitoring and scanning parameters within the Scanning Configuration screen are only enabled
when Custom is selected as the Sensitivity setting from the Basic Configuration screen.
12. Enable or disable Smart Monitoring Enable by selecting the option. The feature is enabled by
default.
When enabled, detector radios monitor their coverage areas for potential failed peers or
coverage area holes requiring transmission adjustments for coverage compensation.
13. Select this option and specify a threshold number between 10 and 10,000. When this
threshold is reached, awareness settings will be overridden with the values specified.