® Brocade Mobility RFS7000-GR Controller Installation Guide Supporting software release 4.1.0.
Copyright © 2010 Brocade Communications Systems, Inc. All Rights Reserved. Brocade, the B-wing symbol, BigIron, DCX, Fabric OS, FastIron, IronPoint, IronShield, IronView, IronWare, JetCore, NetIron, SecureIron, ServerIron, StorageX, and TurboIron are registered trademarks, and DCFM, Extraordinary Networks, and SAN Health are trademarks of Brocade Communications Systems, Inc., in the United States and/or in other countries.
1 Introduction 1 Package contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Document conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Site preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Verifying the installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 5 Secure Installation Procedure 25 Command line interface login procedure for the wireless controller . . . . . . . . . . . . 25 Changing default wireless controller parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 6 Regulatory Information 31 Country selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
About This Document In this chapter • Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • Supported hardware and software . . . . . . . . . . . . . . . . . . . . . . • Document conventions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • Contacting Brocade . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • Warranty coverage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Document conventions This section describes text formatting conventions and important notice formats used in this document. Notes, cautions, and warnings The following notices and statements are used in this manual. They are listed below in order of increasing severity of potential hazards. NOTE A note provides a tip, guidance or advice, emphasizes important information, or provides a reference to related information.
Customer Support Web Site Brocade Support Central Web site, located at www.brocade.com/support provides information and online assistance including developer tools, software downloads, product manuals and online repair requests. Downloads http://www.brocade.com/support/ Manuals http://www.brocade.com/support/ Because quality is our first concern at Brocade, we have made every effort to ensure the accuracy and completeness of this document.
viii Brocade Mobility RFS7000-GR Controller Installation Guide 53-1001946-01
Chapter 1 Introduction In this chapter • Package contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • Document conventions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • Site preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1 Document conventions Document conventions The following graphical alerts are used in this document to indicate notable situations: NOTE Tips, hints, or special requirements that you should take note of. CAUTION Care is required. Disregarding a caution can result in data loss or equipment malfunction. DANGER Indicates a condition or procedure that could result in personal injury or equipment damage.
Site preparation 1 • Brocade strongly recommends the use of an Uninterruptible Power Supply (UPS) that supports the IP-RFS7000 power rating. Not using a UPS can result in data loss or equipment damage due to a power surge or power failure. • Verify that the power connector and socket are accessible at all times during the operation of the equipment. • Do not work with power circuits in dimly lit spaces.
1 4 Site preparation Brocade Mobility RFS7000-GR Controller Installation Guide 53-1001946-01
Chapter 2 Specifications In this chapter • Physical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 • Power cord specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Physical specifications Width 440mm (17.32 in) Height 44.45mm (1.75 in) Depth 390.8mm (15.38 in) Weight 6.12 Kg (13.
2 Power cord specifications • Install surge protection. Be sure to use a surge protection device between the electricity source and the Brocade Mobility RFS7000-GR Controller. • Install an Uninterruptible Power Supply (UPS). A UPS provides continuous power during a power outage. Some UPS devices have integral surge protection. UPS equipment requires periodic maintenance to ensure reliability. A UPS of the proper capacity for the data processing equipment must be purchased.
Chapter LED Codes 3 In this chapter • System status LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 • RJ-45 gigabit Ethernet LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . 11 • SFP gigabit Ethernet LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 • Out of band management port LEDs. . . . . . . . . . . . . . . . . . . . 13 • Out of band management port status LED . . . . . . . . . . . . . . .
3 System status LEDs System status LEDs 6\VWHP 6WDWXV 6\VWHP 6WDWXV )DQ VWDWXV 7HPSHUDWXUH VWDWXV Start up / POST (primary system or redundant system) System Status 1 LED System Status 2 LED Event Off Off Power off Green Blinking Green Blinking Power On Self Test (POST) running Green Solid Green Blinking POST succeeded (Operating System Loading) Green Solid Off POST succeeded (Normal Operation) Amber Blinking Off POST Failure Alternating Green Blinking & Amber Blinking Alternating
3 System status LEDs System Status 1 LED System Status 2 LED Event Green Solid Green Solid Redundancy Feature Enabled Actively Adopting Access Ports Green Solid Amber Blinking No License to adopt Access Ports or No Country Code configured on the controller or License and Country Code configured, but no APs adopted Controller status (redundant system) System Status 1 LED System Status 2 LED Event Off Off Power off Green Solid Off No Redundancy Feature Enabled Green Blinking Green Solid
3 System status LEDs Fan LED Fan LED Event Off System Off / POST Start Green Blinking POST in Process Green Solid All System Fans Normal Operation Amber Solid Redundant Cooling Failure System Operational Amber Blinking System Cooling Failure System will be held in reset until the issue is resolved Temperature status LED Temperature LED Event Off System Off Green Solid Ambient Inlet Temperature is within specified operating limit Amber Solid Ambient Inlet Temperature is near the maximum
3 RJ-45 gigabit Ethernet LEDs RJ-45 gigabit Ethernet LEDs 3RUW VSHHG 3RUW VWDWXV V\PB 3RUW 3RUW VSHHG VWDWXV RJ-45 port speed LED Port Speed LED Event Off 10 Mbps Green Solid 100 Mbps Green Blinking 1000 Mbps Amber Blinking Port Fault RJ-45 port status LED Port Status LED Event Off No Link or Administratively shut down Green Solid Link present Green Blinking Activity: Transmit and Receive Amber Blinking Link Fault Brocade Mobility RFS7000-GR Controller Installation Guide 53-1001
3 SFP gigabit Ethernet LEDs SFP gigabit Ethernet LEDs 3RUW 3RUW VSHHG VWDWXV 8SSHU 3RUW V\PB /RZHU 3RUW SFP port speed LED Port Speed LED Event Green Blinking 1000 Mbps Amber Blinking Module or Tx/Rx Fault Loss SFP port status LED 12 Port Status LED Event Off No Link or Administratively shut down Green Solid Link present / Operational Amber Blinking Module or Tx/Rx Fault Loss Brocade Mobility RFS7000-GR Controller Installation Guide 53-1001946-01
3 Out of band management port LEDs Out of band management port LEDs 3RUW VSHHG 3RUW VWDWXV V\PB Out of band management port speed LED Port Speed LED Event Off 10 Mbps Green Solid 100 Mbps Amber Blinking Port Fault Out of band management port status LED Port Status LED Event Off No Link Green Solid Link present Green Blinking Activity: Transmit and Receive Amber Blinking Link Fault Brocade Mobility RFS7000-GR Controller Installation Guide 53-1001946-01 13
3 14 Out of band management port status LED Brocade Mobility RFS7000-GR Controller Installation Guide 53-1001946-01
Chapter 4 Hardware Setup This chapter contains the following sections: • Cabling information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 • Gigabit Ethernet on the Brocade Mobility RFS7000-GR Controller 16 • Rack mount instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 • Brocade Mobility RFS7000-GR Controller console port setup 20 • Supplying power to the Brocade Mobility RFS7000-GR Controller 22 • Verifying the installation . . . . . . . . . . . . . . . . .
4 Gigabit Ethernet on the Brocade Mobility RFS7000-GR Controller Gigabit Ethernet on the Brocade Mobility RFS7000-GR Controller *LJDELW (WKHUQHW 5- V *LJDELW (WKHUQHW 6)3V V\PB The Brocade Mobility RFS7000-GR Controller has four RJ-45 Gigabit Ethernet ports and four Gigabit SFP (fiber optic) ports. Using the RJ-45 ports requires connecting a Category-6 Ethernet cable to the port. To use the Gigabit SFP ports, first install the SFP Modules.
Gigabit Ethernet on the Brocade Mobility RFS7000-GR Controller 4 Installing Gigabit Ethernet SFPs 1. Open the bail on the transceiver. 2SHQ EDLO WR LQVHUW RU UHPRYH 6)3 WUDQVFHLYHU 2. Insert each of the SFP transceivers into the corresponding ports on the switch.
4 Gigabit Ethernet on the Brocade Mobility RFS7000-GR Controller 3. Once the SFP transceivers are properly seated in their ports, close the bails to lock the transceivers in place.
Gigabit Ethernet on the Brocade Mobility RFS7000-GR Controller 4 4. Insert the fiber optic cables into the installed transceivers.
4 Rack mount instructions Rack mount instructions To install the Brocade Mobility RFS7000-GR Controller in a rack: 1. The rack mounting brackets are installed at the factory. No additional steps are needed. 2. Attach the brackets to the rack using screws appropriate for your rack’s mounting holes.
Brocade Mobility RFS7000-GR Controller console port setup 4 1. Using the supplied console cable (pictured below), connect the Brocade Mobility RFS7000-GR Controller serial port to an RS-232 (DB-9) serial port on a separate computer (the “configuration computer”). 2.
4 Supplying power to the Brocade Mobility RFS7000-GR Controller Supplying power to the Brocade Mobility RFS7000-GR Controller $& LQOHW 5DFN PRXQW EUDFNHW V\PB 1. Plug an approved AC power cord into the power connector at the back of the Brocade Mobility RFS7000-GR Controller. 2. Plug the cord into a standard AC outlet with a voltage range of 100 to 240 VAC.
Verifying the installation 4 • During the Power On Self Test (POST), the System 1 and System 2 LEDs both blink green. • If the POST test fails, the System 1 LED will blink amber. If the POST test succeeds, the System 1 LED will be lit solid green. • As the software is initialized, the System 2 LED will blink green. • After the software has finished initializing, the System 1 LED will be lit solid green and the bottom System 2 LED will be off.
4 24 Verifying the installation Brocade Mobility RFS7000-GR Controller Installation Guide 53-1001946-01
Chapter Secure Installation Procedure 5 In this chapter • Command line interface login procedure for the wireless controller 25 • Changing default wireless controller parameters. . . . . . . . . . 26 This installation procedure explains how to login to the Command Line Interface for initial configuration. Through this process the wireless controller is configured with a set of default values for specific features.
5 Changing default wireless controller parameters Password is same as default password, please change the password Enter old password: Enter new password: Re Enter new password: Password for user 'admin' changed successfully RFS7000> 5. Once Username and Password credentials are validated, the below prompt will returned. Enter “Enable” to get into execution mode. RFS7000>enable RFS7000# 6.
Changing default wireless controller parameters 5 NOTE The password a%defMyj is only an example. Enter a unique password in place of this example. 4. Country code must be set to the appropriate country in order to have proper channel of operations. Access Points are adopted after the country code is set. a. Enter “wireless configuration mode” RFS7000(config)#wireless b. Execute the following in wireless configuration mode.
5 Changing default wireless controller parameters NOTE The pre-shared key: acdefab12345678abcdefab12345678abcdefab12345678abcdefab 12345678 is only an example. Enter a unique pre-shared key in place of this example. 7. Self Signed certificates should be replaced with a private certificate. a. The controller ships with a default trust point using a default self-signed certificate. This certificate is associated with the hotspot and onboard RADIUS server.
Changing default wireless controller parameters 5 -----BEGIN CERTIFICATE REQUEST----MIIB2jCCAUMCAQAwZzELMAkGA1UEBhMCVVMxCzAJBgNVBAgTAkNBMREwDwYDV QQH EwhTYW4gSm9zZTENMAsGA1UEChMETW90bzEWMBQGA1UECxMNV0xBTiBkaXZpc 2lv bjERMA8GA1UEAxMIbW90b0ZpcHMwgZ8wDQYJKoZIhvcNAQEBBQADgY0AMIGJA oGB AMHr9U1XAEhhEInvVHsyFkvjnKcX7RVbiC01HkGrBMTipKZMx/vQ/zbHlzNcj 72k FwH9aJeI68tOEjvOK/9287UUqt9T73cti+VZf9h8rmvWTSQsOZ5GogGhYvc/n Jee mQF7OSjXi2J1CjkIhQTarpGv9/TW2RSWOGFa5wtwbt0BAgMBAAGgMzAxBgkqh kiG 9w0BCQ4xJDAiMAsGA1UdDwQEAwIEsD
5 Changing default wireless controller parameters i. Enable http and https access to the hotspot page: RFS7000(config)#ip http secure-server RFS7000(config)#ip http server j. Associate the newly created trustpoint with the onboard RADIUS server using the example below: RFS7000(config)#radius-server local RFS7000(config-radsrv)#ca trust-point externalCert RFS7000(config-radsrv)#server trust-point externalCert k. Restart the RADIUS server. RFS7000(config)#service radius restart l.
Chapter 6 Regulatory Information • Country selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • Laser devices - Gigabit Ethernet SFP option. . . . . . . . . . . . . . • Radio frequency interference requirements - FCC . . . . . . . . . • Radio frequency interference requirements - Canada . . . . . . • CE marking and European Economic Area (EEA) . . . . . . . . . . • Waste Electrical and Electronic Equipment (WEEE) . . . . . . . .
6 Radio frequency interference requirements - FCC Class 1 Laser devices are not considered to be hazardous when used for their intended purpose. The following statement is required to comply with US and international regulations: CAUTION This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
CE marking and European Economic Area (EEA) 6 CE marking and European Economic Area (EEA) Statement of compliance Brocade hereby declares that this device is in compliance with all the applicable Directives, 2004/108/EC, 2006/95/EC. A Declaration of Conformity may be obtained from http://www2symbol.com/doc/ Waste Electrical and Electronic Equipment (WEEE) For information on WEEE, please go to: http://www.brocade.
6 34 Waste Electrical and Electronic Equipment (WEEE) Brocade Mobility RFS7000-GR Controller Installation Guide 53-1001946-01