sysmon port port-crc-test polling-period
5
sysmon port port-crc-test polling-period
Configures the polling period for the port CRC error monitoring test.
Syntax sysmon port port-crc-test polling-period secs
Command
Default
Parameters secs Specifies the polling period in seconds. The range of values is 0 through
65535. The default value is 60 seconds.
Command
Modes
Global configuration mode.
Usage
Guidelines
Examples The following example configures the port CRC error monitoring test to run every 60 seconds.
Brocade(config)# sysmon port port-crc-test polling-period 60
History
Related
Commands
sysmon port port-crc-test
Release Command History
Multi-Service IronWare R05.5.00 This command was introduced