Service IronWare Administration Guide (Supporting R05.6.00) User Manual

Multi-Service IronWare Administration Guide 141
53-1003028-02
sysmon port port-crc-test threshold
5
sysmon port port-crc-test threshold
Configures the threshold for diagnostic action for the port CRC error monitoring test.
Syntax sysmon port port-crc-test threshold num-failures num-polls
Command
default
The default threshold is 3 failed test runs out of 5 polls.
Parameters num-failures Specifies the number of failed test runs. The range of values is 1 through 31.
num-polls Specifies the number of polls (tests). The range of values is 2 through 31.
Command
Modes
Global configuration mode.
Usage
Guidelines
Examples The following example configures the threshold to trigger the configured diagnostic action if the
test fails more than three times in five consecutive polls.
Brocade(config)# sysmon port port-crc-test threshold 3 5
History
Related
Commands
sysmon port port-crc-test
Release Command History
Multi-Service IronWare R05.5.00 This command was introduced