Service IronWare Administration Guide (Supporting R05.6.00) User Manual
Multi-Service IronWare Administration Guide 161
53-1003028-02
CFM monitoring and show commands
6
The show cfm brief show a summary of the configured MEPs and RMEPs.
Syntax: show cfm [domain name] [ma ma-name] brief
MIP DIsplays the associated MIP
VLAN DIsplays the associated VLAN.
TABLE 29 Show cfm brief output description
This field... Displays...
Domain The Domain is the network or the part of the network for which faults in connectivity
are displayed.
Index The Domain Index.
Level The level is the domain level in the range 0-7. The levels can be:
• Customer’s MD levels: 5 - 7
• Provider’s MD levels: 3 - 4
• Operator’s MD levels: 0 – 2
Maintenance Association The maintenance association name.
Ma Index The Maintenance Association Index.
CCM interval The time interval between two successive Continuity Check messages (CCMs) that
are sent by MEPs in the specified Maintenance Domain.
VLAN ID The VLAN identifier of the maintenance association.
VPLS ID The VPLS identifier of the maintenance association.
Priority The priority of the CCM messages, sent by MEPs, in the range 0-7.
Numof MEP The number of MEPs configured.
Num of RMEP The number of remote MEPs configured
remepstart The number of RMEPs in the start state.
rmepfail The number of RMEPs that have failed.
rmepok The number of RMEPs in an OK state.
TABLE 28 Show CFM output descriptions
This field... Displays...
Brocade#show cfm brief
Domain: md2
Index: 1
Level: 6 Num of MA: 1
Maintenance association: ma2
MA Index: 1
CCM interval: 10000 ms
VLAN ID: 2
Priority: 6
Num of MEP: 1 Num of RMEP: 1
rmepstart: 0 rmepfail: 0 rmepok 1