Service IronWare Administration Guide (Supporting R05.6.00) User Manual
232 Multi-Service IronWare Administration Guide
53-1003028-02
CFM monitoring for ISID
6
Show commands
The following show commands provide output for each component of the sample configuration.
Show cfm connectivity
Assume link between DUT 2 and 4 goes down. RMEP(DUT4‘s MEP) will get failed in DUT1 and
DUT3. At this time DUT1 and 2 will start transmitting CCM with RDI bit set since RMEP has failed.
Brocade_DUT_1#show cfm connectivity
Domain: customer Index: 1
Level: 7
Maintenance association: admin
MA Index: 1
CCM interval: 1000 ms
VLAN ID: 100
Priority: 7
ETH-AIS TX: DISABLED
ETH-AIS RX: DISABLED
ETH-AIS Interval: 10 sec
RMEP MAC VLAN/PEER AGE PORT SLOTS STATE AIS_STATE
==== ============== ========== ======= ======== ========= ======== =========
2 0000.00ef.2a0b 100 799 1/1 1 OK None
3 0000.0011.86d1 100 400 1/1 1 FAILED None
Brocade_DUT_1#
show cfm connectivity
The show cfm connectivity command shows the RDI received by RMEP.
The following command shows the RDI received by RMEP
Brocade_DUT_3#show cfm connectivity domain customer ma admin rmep-id 1
Domain: customer Level: 7
Maintenance association: admin VLAN VLAN/VPLS/VLL ID: 100 Priority: 7
CCM interval: 1000 ms
RMEP MAC PORT Oper Age CCM RDI Port Intf Intvl Seq core
State Val Cnt Status Status Error Error Fault level
==== =============== ===== ===== ======= ===== ===== ==== ====== ====== ===== ============
1 0000.0011.3301 1/2 OK 590 590 Y 0 0 N N N
Brocade_DUT_3#
Brocade_DUT_1#show cfm connectivity domain customer ma admin rmep-id 2
Domain: customer Level: 7
Maintenance association: admin VLAN VLAN/VPLS/VLL ID: 100 Priority: 7
CCM interval: 1000 ms
RMEP MAC PORT Oper Age CCM RDI Port Intf Intvl Seq core
State Val Cnt Status Status Error Error Fault level
==== =============== ===== ===== ======= ==== ==== ==== ====== ====== ===== ===========
2 0000.00ef.2a0b 1/1 OK 690 590 Y 0 0 N N N
Brocade_DUT_1#
Syntax: show cfm connectivity domain customer ma admin rmep-id id