Service IronWare Administration Guide (Supporting R05.6.00) User Manual

Multi-Service IronWare Administration Guide 239
53-1003028-02
Frame Loss Measurement
6
Starting LMM Sessions
Start the responder before starting the initiator.
CE-2 Configuration
BrocadeCE-2(config)# cfm
BrocadeCE-2(config-cfm)# loss-measurement lmm responder 1
BrocadeCE-2(config-cfm-loss-measurement-lmm-responder-1)#start now
CE-1 Configuration
BrocadeCE-1(config)# cfm
BrocadeCE-1(config-cfm)# loss-measurement lmm initiator 1
BrocadeCE-1(config-cfm-loss-measurement-lmm-initiator-1)#start now
Stopping LMM Sessions
Stop the initiator before stopping the responder.
CE-1 Configuration
BrocadeCE-1(config)# cfm
BrocadeCE-1(config-cfm)# loss-measurement lmm initiator 1
BrocadeCE-1(config-cfm-loss-measurement-lmm-initiator-1)#stop now
CE-2 Configuration
BrocadeCE-2(config-cfm)# loss-measurement lmm responder 1
BrocadeCE-2(config-cfm-loss-measurement-lmm-responder-1)#stop now
Clearing history statistics per session
BrocadeCE-1(config-cfm)# loss-measurement lmm initiator 1
BrocadeCE-1(config-cfm-loss-measurement-lmm-initiator-1)#clear-stat
Clearing history statistics globally
BrocadeCE-1(config-cfm)# loss-measurement clear-stat
Syslog messages
Syslogs will be raised for the following cases:
When the LMM session is started.
When the LMM session is stopped.
When the Average Frame Loss Ratio is greater than the Threshold Average Frame Loss Ratio.
When the Maximum Frame Loss Ratio is greater than the Threshold Maximum Frame Loss
Ratio.
Syslog message display output
The following are the Syslog message outputs displayed for various cases:
When the LMM session started