Service IronWare Administration Guide (Supporting R05.6.00) User Manual
258 Multi-Service IronWare Administration Guide
53-1003028-02
Synthetic loss measurement
6
Syntax: Show cfm loss-measurement slm statistics session index
DUT1# show cfm loss-measurement slm statistics 1
HISTORY TABLE :
Flag - S:Suspect
-----------------------------------------------------------------------------------------------
Index Flag Start Elapsed TxFwd RxFwd TxBck RxBck FLR(ratio) BLR(ratio)
-----------------------------------------------------------------------------------------------
5 - 16:29:56 00:00:05 5 5 5 5 0.00000 0.00000
4 - 16:29:39 00:00:14 14 4 4 4 0.71428 0.00000
3 - 16:29:25 00:00:04 4 0 0 0 1.00000 0.00000
2 - 16:29:17 00:00:03 3 0 0 0 1.00000 0.00000
1 - 16:27:14 00:00:03 3 0 0 0 1.00000 0.00000
==============================================================================================
Syntax: show cfm loss-measurement slm statistics detailed session_index row index
DUT1# show cfm loss-measurement slm statistics detailed 1 2
HISTORY TABLE :
Flag - S:Suspect
------------------------------------------------
Index : 2
Flag : -
Start : 16:29:56
Elapsed : 00:00:05
TxFwd : 5
RxFwd : 5
TxBck : 5
RxBck : 5
FLR(ratio) Max : 0.00000
Session Type initiator or responder
Domain domain name
MA ma name
Source MEP source mep id
Target MEP target mep id or RMEP
COS data priority loss in which needs to be monitored
Start time Configured start time
Start time type Immediate, relative, fixed, periodic
Stop time configured stop time
Stop time type Immediate, relative, fixed, periodic
Tx interval (sec) transmission interval in sec, only for initiator
Measurement interval measurement-interval in minutes, only for initiator
Forward Average configured forward average threshold, for initiator
Forward Max configured forward maximum threshold, for initiator
Backward Average configured backward average threshold, for initiator
Backward Max configured backward maximum threshold, for initiator
TABLE 35 show cfm loss-measurement slm output
Row Definition