Service IronWare Administration Guide (Supporting R05.6.00) User Manual
Multi-Service IronWare Administration Guide 341
53-1003028-02
Syslog messages
A
• Alerts
• Critical
• Errors
• Warnings
• Notifications
• Informational
• Debugging
TABLE 58 Syslog messages system
Message level Message Explanation
Alert ISIS Memory Limit Exceeded IS-IS is requesting more memory than is available.
Alert System Power supply num, location, failed A power supply has failed.
The num is the power supply number.
The location describes where the failed power
supply is in the chassis.
Alert System power type Power Supply num,
location, state
The power type refers to AC or DC power supply.
The num is the power supply number as
positioned in the chassis.
The location describes where the power supply is
in the chassis in relation to its state.
The state refers to how the power supply is
functioning in the chassis.
The state can be one of the following:
• Installed (OK) - The power supply is installed
and ok.
• Installed (Failed or Disconnected)- The power
supply has failed, or the power cord is
disconnected.
• Not Installed (FAILED) - The power supply is
physically removed from the chassis.
Alert System Fan num, location, failed A fan has failed.
The num is the power supply number.
The location describes where the failed power
supply is in the chassis. The location can be one
of the following