Service IronWare Administration Guide (Supporting R05.6.00) User Manual

26 Multi-Service IronWare Administration Guide
53-1003028-02
Configuring SNMP ifIndex
2
Power supply failure
Fan failure
Cold start
Link up
Link down
Bridge new root
Bridge topology change
Module insert
Module remove
Redundant module
Metro-ring
MPLS
BGP4
OSPF
VRRP
VSRP
To stop link down occurrences from being reported, enter the following command.
Brocade(config)# no snmp-server enable traps link-down
Syntax: [no] snmp-server enable traps trap-type
A list of traps is available in the Unified IP MIB Reference.
Configuring SNMP ifIndex
This section explains how ifIndex values are assigned on Brocade devices.
On Brocade NetIron CES and Brocade NetIron CER only
On the Brocade NetIron CES and Brocade NetIron CER, the system automatically assign 64 indexes
to each module on the device. This value is not configurable.
On Brocade NetIron XMR and Brocade MLX series only
On Brocade NetIron XMR and Brocade MLX series devices, SNMP Management Information Base
(MIB) uses Interface Index (ifIndex) to assign a unique value to each port on a module or slot. The
number of indexes that can be assigned per module is 20, 40, or 64, depending on the number of
ports on the module.
Enter the following to change the number of indexes per module.
Brocade(config)# snmp-server max-ifindex-per-module 40
Syntax: [no] snmp-server max-ifindex-per-module [20 | 40 | 64]