IP configuration requirements
34
IP configuration requirements
To be able to use SNMP Monitor for performance monitoring, make sure the following requirements
are met:
Ensure that SNMP is enabled on the devices you want to monitor and that SNMP community
strings have been defined for set and get operations.
Make sure discovery has been run and the devices appear on the Network Object Manager
tree. If a device is not on the tree, add the device using Network Object Manager.
Define what data you want to collect.
If you need to monitor devices within specific device groups, you must create the device
groups.
You must have the SNMP Monitor privilege in your user account or role.
Management application comes with default MIB files, such as standard MIB and Brocade
proprietary MIB files.
IP real-time performance monitoring
Real-time performance monitoring allows you to view a snapshot of current performance data. You
can enable real-time performance monitoring without configuring historical data collectors. The
data is not stored in the database. Performance monitoring allows you to define a data collector by
mapping a Management Information Base (MIB) object to a unit name (refer to “MIB data
collectors” on page 1143).
Real-time performance measures are built-in expressions. The following measures are available:
Monitoring real-time performance
If no products have been selected for real-time performance monitoring, you can select products
and data collectors by taking the following steps.
1. Select Monitor > Performance > Real Time Graphs/Tables.
The Select Sources - Real Time Graphs/Tables dialog box displays, as shown in .Figure 465 on
page 1114.
Device measures
Power Allocation (NS)
Power Allocation % (NS)
CPU utilization
Memory utilization
Temperature
Port measures
Optics
Power Allocation (NS)
Consumption (W)
Power Consumption %
Input and output utilization
Throughput
Input and output errors
FC Port transmit and receive utilization (VDX only)
FC Port transmit and receive in megabits per second (VDX
only)