User Manual v12.1.0 Instruction Manual

1452 Brocade Network Advisor SAN + IP User Manual
53-1002949-01
FC troubleshooting
42
6. Select a port row in the Selected Ports table to display the detailed status in the Status Details
of the Selected Row table.
The Status Details of the Selected Row table displays with the details of the port selected for
diagnosis, the details of the tests performed, the results of the test, as well as short
description of the test results. The following table details the messages that display depending
on the success or failure of the operations and tests.
TABLE 138 Status Detail messages
Operation/Test Possible message
Disable the source or destination
port
Disabled the port slot_number/port_number of the switch
switch_IP_address.
Failed to disable the port slot_number/port_number of the switch
switch_IP_address.
Reason: CAL_error_message
Enable the diagnostic mode on
source or destination E ports
Enabled diagnostic mode on port slot_number/port_number of the
switch switch_IP_address.
Failed to enable diagnostic mode on port slot_number/port_number of
the switch switch_IP_address.
Reason: CAL_error_message
Enable the source or destination
port
Enabled the port slot_number/port_number of the switch
switch_IP_address.
Failed to enable the port slot_number/port_number of the switch
switch_IP_address.
Reason: CAL_error_message
Disable the diagnostic mode on
source or destination D ports
Disabled diagnostic mode on port slot_number/port_number of the
switch switch_IP_address.
Failed to disable diagnostic mode on port slot_number/port_number of
the switch switch_IP_address.
Reason: CAL_error_message
Lost connectivity to switch while
test is in progress
Connection failed to the switch during the operation.
Diagnostic port test timed out
The Management application
waits 30 minutes to complete
the test. If not completed, the
test times out.
Diagnostic port test time-out. You may need to change the port
configuration before retrying.
Electrical Loopback Test Successfully completed Electrical Loopback Test on port
slot_number/port_number of the switch switch_IP_address.
Electrical Loopback Test failed on port slot_number/port_number of the
switch switch_IP_address. Reason: CAL_error_message
Electrical Loopback Test skipped on port
slot_number/port_number of
the switch switch_IP_address.
Reason: CAL_error_message
Optical Loopback Test Successfully completed Optical Loopback Test.
Optical Loopback Test failed
Optical Loopback Test skipped.
Reason: CAL_error_message