User Manual v12.1.0 Instruction Manual
Brocade Network Advisor SAN + IP User Manual 1615
53-1002949-01
Accessing Flow Vision from other management application features
44
Accessing Flow Vision from other management application features
Access Flow Vision features through the following management application features:
• Frame Viewer
• Bottleneck detection
• Fibre Channel trace route, ping, and port connectivity troubleshooting features.
Frame Viewer
Select a frame from the Discarded Frames dialog box for a device or port and select Add Flow to
launch the Add Flow Definition dialog box. The Add Flow Definition dialog box will be populated with
the following information when available:
• Source Device - Source ID
• Destination Device - Destination ID
• Ingress port - Transmit port
• Egress Port - Receive port
• Monitor - Bidirectional
NOTE
If the source or destination ID are not available, the source and destination device fields will contain
asterisks if the target switch supports learning.
Refer to the Frame Viewer section of SAN Device Configuration chapter for more information on
accessing and using Frame Viewer and viewing discarded frames. Refer to “Frame viewer” on
page 550.
MAPS
Through the Traffic Monitoring category in the Monitoring and Alerting Policy Suite (MAPS) feature,
you can view a filtered list of MAPS violations for imported flows or sub-flows. You can also create
MAPS policies for events related to flows and sub-flows. For more information on accessing and
using the MAPS features, refer to Chapter 50, “Monitoring and Alerting Policy Suite”.
Fixed value Fixed value Fixed value Not specified Fixed value Not specified Not specified LUN monitor without Frame
Type needs both source
device and destination
device values
(ASIC limitation)
Fixed value Fixed value Not specified Fixed value Fixed value Not specified Not specified LUN monitor without Frame
Type needs both source
device and destination
device values
(ASIC limitation)
TABLE 158 Flow parameter combinations for Flow Monitor
Source
Device
Destination
Device
Ingress Port Egress Port LUN IDs Frame Type Bidirectional Description/ Notes