User Manual v12.1.0 Instruction Manual
1694 Brocade Network Advisor SAN + IP User Manual
53-1002949-01
Configuration rules
47
Predefined conditions
The Management application provides predefined conditions. Table 167 lists the predefined
conditions that can be used in a block or at the configuration rule level. For example, interface
conditions should be used in a port or LAG interface block and SNMP conditions can be used at the
rule level.
TABLE 167 Predefined conditions
Name Description Use
regular
expression
Matches/
Not Matches
Configuration Lines in
exact
order
Network OS Interface shutdown check Checks whether the interface is
configured as shutdown. This
condition should be used within an
interface block.
No Matches shutdown No
Network OS Interface NOT shutdown
check
Condition test fails if the interface is
shutdown.
No Not Matches shutdown No
Network OS Interface sflow Enabled
check
Checks whether sFlow is enabled on
the interface. This condition should
be used within an interface block.
No Matches sflow enable
sflow sample-rate
32768
Yes
Network OS Interface All VLANs check Checks whether the interface is
configured to be part of all VLANs.
This condition should be used within
an interface block.
No Matches switchport trunk
allowed vlan all
No
Network OS Interface Trunk mode
check
Checks whether the interface is
configured to be in trunk mode. This
condition should be used within an
interface block.
No Matches switchport
switchport mode
trunk
Yes
Network OS Interface Switchport
mode check
Checks whether the Network OS
interface is configured to be a
switchport or not. If not configured,
the test will fail.
No Matches switchport No
Network OS Interface Access mode
check
Checks whether the interface is
configured to be in access mode. This
condition should be used within an
interface block.
No Matches switchport
switchport mode
access
Yes
Network OS Interface Port Profiled
check
Checks whether the interface port is
profiled. This condition should be
used within an interface block.
No Matches port-profile-port No
IronWare OS Interface shutdown
check
Checks whether the IronWare device
port is in shutdown state. (This is not
applicable for Ethernet router
products.) This condition should be
used within an interface block.
No Matches disable No
IronWare OS Interface sflow check Checks whether sFlow is configured
on the IronWare device port. This
condition should be used within an
interface block.
No Matches sflow-forwarding
sflow sample 32768
Yes
IronWare OS SNMP community
Strings configured check
Checks whether SNMP community
strings are configured.
Yes Matches snmp-server
community .*
No