User Manual v12.3.0 Owner manual

Brocade Network Advisor SAN + IP User Manual 1315
53-1003155-01
Cascaded FICON fabric
30
NOTE
To enable DLS, all switches in the fabric must be 8 Gbps or faster and running Fabric OS 6.4 or
later.
NOTE
You must enable FMS mode for logical fabrics running Fabric OS 7.3.0 or later.
(Optional) Turns on FICON Management Server (FMS) mode on all switches.
Consider the following information when enabling FMS mode:
- If switches are running Fabric OS 7.0 and later, FMS mode will not be enabled unless the
switches have an active CUP license.
- If switches are running Fabric OS earlier than version 7.0 and do not have a CUP license,
after successful configuration, you can access the Port Connectivity (Allow/Prohibit)
matrix, but the host system cannot communicate with the FICON Management Server
unless you install a CUP license. If a CUP license is later installed on these switches, then
FMS mode must be re-enabled on these switches.
- For logical fabrics running Fabric OS 7.1 or later, you can enable FMS mode when logical
switches are configured to allow XISL use.
Configuring a cascaded FICON fabric
The FICON wizard automatically creates HIFC settings that support a cascaded FICON fabric.
1. Select Configure > FICON > Configure Fabric or right-click a fabric in the product tree and
select FICON > Configure Fabric.
The Configure Cascaded FICON Fabric screen of the FICON Configuration dialog box displays,
as shown in Figure 582.