User Manual v12.3.0 Owner manual

Brocade Network Advisor SAN + IP User Manual 2099
53-1003155-01
Host adapter reports
52
Table 210 describes the SFP and POM fields of the Adapters Faulty SFP Report.
TABLE 210 Adapters Faulty SFP report fields and components
Field/Component Description
SFP Supported Whether the SFP is supported or not.
Connector Type The type of port connector; for example, LC. SC, or Cu (copper cable).
Transceiver The type of transceiver; for example, SFP or SFP+.
Media The type of media for the transceiver; for example, single mode.
Speed The port speed.
Extended ID The identifier for the extended link.
Encoding Displays how the extended link is encoded, for example, 8B10B.
Baud Rate The transmission rate, roughly equivalent to the number of bits per second.
Length 9U1 The length of the single-mode fiber-optic cable, used in situations where gigabit
performance is not required (for distances greater than 100 meters).
Length 9U2 The length of the single-mode fiber-optic cable, used in situations where gigabit
performance is not required (for distances greater than 100 meters).
Length 50u The length of the 50u fiber-optic cable (for distances greater than 10 meters).
Length 62.5u The length of the 62.5u fiber-optic cable (for distances greater than 10 meters).
Length Cu The length of the copper cable (for distances greater than 1 meter, where optimum
performance is required).
Vendor Name The vendor of the extended link.
Vendor OUI The vendor’s organizational unique identifier (OUI).
Vendor Part The part number of the extended link.
Revision The revision level of the extended link.
Wavelength The wavelength translation, which enables longer reach through lower attenuation.
Options Displays details about the transceiver; for example, the type of port connector, type of
transceiver, and enable/disable status.
BR Max The upper bit rate limit at which the SFP transceiver meets its specifications.
BR Min The lower bit rate limit at which the SFP transceiver meets it specifications.
Serial # The serial number of the SFP transceiver.
Date Code The date the SFP was manufactured transceiver.
Temperature (c) The port temperature, measured in Celsius.
Bias Current (mA) The low-level DC current (the Bias Current), measured in mA.
Tx Power (mW) The transmitted power, measured in mW.
Rx Power (mW) The received power, measured in mW.
Voltage (V) The voltage; for example, 1.8V, 3.3V, or 5.0V.
Alarm/Warning Indicates whether an alarm has been triggered.