User Manual v12.3.0 Owner manual

2140 Brocade Network Advisor SAN + IP User Manual
53-1003155-01
Call Home Event Tables
B
TABLE 212 # Thermal Events
Event reason code FRU code/Event type Description Severity
800 DVP/LIM/HW High temperature warning. 3
801 DVP/LIM/HW Critically hot temperature warning. 3
802 DVP/LIM/HW Port card shutdown due to thermal violations. 3
805 SWM/SBAR/HW High temperature warning. 3
806 SWM/SBAR/HW Critically hot temperature warning. 3
807 SWM/SBAR/HW SBAR module shutdown due to thermal violations. 3
810 CTP/HW High temperature warning. 3
811 CTP/HW Critically hot temperature warning. 3
812 CTP/HW CTP shutdown due to thermal violations. 3
850 CTP/HW System shutdown due to CTP thermal threshold violations. 4
TABLE 213 Fabric OS Events
Event reason code FRU code/Event type Description Severity
N/A Ethernet Switch is not reachable. 3
N/A SW-Missing Switch is missing from the fabric. 3
1009 MS-1009 Error in registered link incident record (RLIR). 4
1021 MAPS-1021 Core blade redundancy 3
1021 MAPS-1021 Error ports 3
1021 MAPS-1021 Faulty CPs 3
1021 MAPS-1021 Faulty or absent Blades 3
1021 MAPS-1021 Faulty or absent Fans 3
1021 MAPS-1021 Faulty or absent Power Supplies 3
1021 MAPS-1021 Faulty Ports 3
1021 MAPS-1021 Faulty Temperature sensors 3
1021 MAPS-1021 Faulty WWN Cards 3
1021 MAPS-1021 Flash usage is out of range 3
1021 MAPS-1021 Marginal ports 3
1021 MAPS-1021 Missing SFPs 3
1402 FW-1402 Flash usage is out of range (Fabric OS version 6.0 or earlier). 3