Reference v4.1.0 Instruction Manual

Network OS Command Reference 1001
53-1003115-01
show running-config cee-map
2
show running-config cee-map
Displays the Converged Enhanced Ethernet (CEE) map.
Synopsis show running-config cee-map [precedence | priority-group-table [pgid]| priority-table | remap
{fabric-priority | lossless-priority}]
Operands precedence Displays only the precedence of the default CEE map.
priority-group-table Without a specified priority group ID, displays the priority group table for
each priority group ID.
pgid Specifies one priority group ID.
priority-table Displays the configured priority table map.
remap fabric-priority Displays the fabric priority for the Brocade VCS Fabric QoS.
remap lossless-priority Displays the lossless priority for the Brocade VCS Fabric QoS.
Defaults None
Command Modes Privileged EXEC mode
Description Use this command to display properties of the configured CEE map. Without parameters, the
command displays the precedence of the default CEE map, priority group table for each priority
group ID, the configured priority table map, and the fabric priority and lossless priority for the
Brocade VCS Fabric QoS.
Usage Guidelines None
Examples To display the CEE map:
switch(config)# show running-config cee-map
cee-map default
precedence 1
priority-group-table 1 weight 40 pfc on
priority-group-table 15.0 pfc off
priority-group-table 15.1 pfc off
priority-group-table 15.2 pfc off
priority-group-table 15.3 pfc off
priority-group-table 15.4 pfc off
priority-group-table 15.5 pfc off
priority-group-table 15.6 pfc off
priority-group-table 15.7 pfc off
priority-group-table 2 weight 60 pfc off
priority-table 2 2 2 1 2 2 2 15.0
remap fabric-priority priority 0
remap lossless-prioirty priority 0
!