Reference v4.1.0 Instruction Manual
Network OS Command Reference 1139
53-1003115-01
show running-config system-monitor
2
show running-config system-monitor
Displays the system monitor configuration.
Synopsis show running-config system-monitor [fan | power | temp | cid-card | sfp | compact-flash | MM |
LineCard | SFM]
Operands fan Displays the threshold and alert setting for the FAN component.
power Displays the threshold and alert setting for the power component.
temp Displays the threshold for the temperature sensor component.
cid-card Displays the threshold for the CID card component.
sfp Displays the threshold for the small form factor pluggable (SFP) device.
compact-flash Displays the threshold for the compact flash device.
MM Displays the threshold for the management module.
LineCard Displays the threshold for the line card.
SFM Displays the threshold for the switch fabric module.
Defaults None
Command Modes Privileged EXEC mode
Description Use this command to display the running system monitor configuration.
Usage Guidelines This command is supported only on the local switch.
Examples
switch# show running-config system-monitor
system-monitor fan threshold marginal-threshold 1 down-threshold 2
system-monitor fan alert state removed action raslog
system-monitor power threshold marginal-threshold 0 down-threshold 1
system-monitor power alert state removed action raslog
system-monitor temp threshold marginal-threshold 1 down-threshold 2
system-monitor cid-card threshold marginal-threshold 1 down-threshold 0
system-monitor cid-card alert state inserted,faulty action email
system-monitor sfp alert state none action none
system-monitor compact-flash threshold marginal-threshold 1 down-threshold 0
system-monitor MM threshold marginal-threshold 1 down-threshold 0
system-monitor LineCard threshold marginal-threshold 1 down-threshold 0
system-monitor LineCard alert state removed action raslog
system-monitor SFM threshold marginal-threshold 1 down-threshold 0
See Also show system monitor, system-monitor-mail