Reference v4.1.0 Instruction Manual
1156 Network OS Command Reference
53-1003115-01
show sflow
2
show sflow
Displays sFlow configuration information and statistics.
Synopsis show sflow [interface {fortygigabitethernet rbridge-id/slot/port |
gigabitethernet rbridge-id/slot/port | tengigabitethernet rbridge-id/slot/port}] | all
Operands all Displays all sFlow information and statistics.
interface Displays sFlow information for an Ethernet interface.
fortygigabitethernet Specifies a valid 40-gigabit Ethernet interface.
rbridge-id Specifies the RBridge ID.
slot Specifies a valid slot number.
port Specifies a valid port number.
gigabitethernet Specifies a valid 1-gigabit Ethernet interface.
rbridge-id Specifies the RBridge ID.
slot Specifies a valid slot number.
port Specifies a valid port number.
tengigabitethernet Specifies a valid 10-gigabit Ethernet interface.
rbridge-id Specifies the RBridge ID.
slot Specifies a valid slot number.
port Specifies a valid port number.
Defaults sFlow is disabled on all interfaces.
Command Modes Privileged EXEC mode
Description Use this command to display sFlow configuration information and statistics.
Usage Guidelines The gigabitethernet rbridge-id/slot/port parameter is used only on Brocade VDX 6710,
Brocade VDX 8770-4, and Brocade VDX 8770-8 switches.
Examples To display sFlow statistics on the 10-gigabit Ethernet interface 15/0/4:
switch# show sflow interface tengigabitethernet 15/0/4
sFlow info for interface Ten Gigabit Ethernet 15/0/4
------------------------------------------------
Configured sampling rate: 100 pkts
Actual sampling rate: 100 pkts
Counter polling interval: 100 secs
Samples received from hardware: 32
Port backoffThreshold : 272
Counter samples collected : 147
To display sFlow statistics on 1-gigabit Ethernet interface 22/0/1:
switch# show sflow interface gigabitethernet 22/0/1
---------------------------------------------------
sFlow info for interface Gigabit Ethernet 22/0/1
Configured sampling rate: 32768 pkts