Reference v4.1.0 Instruction Manual

Network OS Command Reference 1287
53-1003115-01
switchport private-vlan trunk native-vlan
2
switchport private-vlan trunk native-vlan
Sets native private VLAN (PVLAN) characteristics on a trunk port.
Synopsis switchport private-vlan trunk native-vlan vlan_id
no switchport private-vlan trunk native-vlan
Operands vlan_id Specifies a VLAN to transmit and receive through the Layer 2 interface.
Refer to the Usage Guidelines.
Defaults None
Command Modes Interface subtype configuration mode
Description Use this command to set the native PVLAN characteristics of the Layer 2 trunk interface for
classifying untagged traffic.
Usage Guidelines Enter no switchport trunk native-vlan to reset the native VLAN to the default setting.
Native VLAN configuration is not supported for a port in private vlan trunk promiscuous mode.
On the Brocade VDX family of switches, VLANs are treated as interfaces from a configuration point
of view. By default, all the DCB ports are assigned to VLAN 1 (VLAN ID equals 1). Valid VLAN IDs
are as follows:
On Brocade VDX 8770 switches: 1 through 4086 for 802.1Q VLANs (VLAN IDs 4087
through 4095 are reserved on these switches), and 4096 through 8191 for service or
transport VFs in a Virtual Fabrics context.
On all other Brocade VDX switches: 1 through 3962 for 802.1Q VLANs (VLAN IDs 3963
through 4095 are reserved on these switches), and 4096 through 8191 for service or
transport VFs in a Virtual Fabrics context.
Examples To set native PVLAN characteristics for a VLAN whose VLAN ID is 120:
switch(config)# interface tengigabitethernet 178/0/9
switch(conf-if-te-178/0/9)# switchport private-vlan trunk native-vlan 120
See Also switchport mode private-vlan, switchport private-vlan association
trunk,switchport private-vlan trunk allowed vlan