sflow polling-interval (global version)
2
sflow polling-interval (global version)
Configures the polling interval globally.
Synopsis sflow polling-interval interval_value
no sflow polling-interval interval_value
Operands interval_value Specifies a value in seconds to set the polling interval. Valid values range
from 1 through 65535 seconds.
Defaults The default is 20.
Command Modes Global configuration mode
Description Use this command to configure the polling interval globally. The interval is the maximum number
of seconds between successive samples of counters to be sent to the collector.
Usage Guidelines Enter no sflow polling interval interval_value to return to the default value.
Examples To set the polling interval to 135 seconds:
switch(config)# sflow polling-interval 135