Reference v4.1.0 Instruction Manual
Network OS Command Reference 733
53-1003115-01
show diag burninstatus
2
show diag burninstatus
Displays the diagnostics burn-in status or system verification status stored in the nonvolatile
storage memory in the switch.
Synopsis show diag burninstatus [rbridge-id rbridge-id]
Operands rbridge-id rbridge-id Specifies the RBridge ID for the switch.
Defaults None
Command Modes Privileged EXEC mode
Description Use this command to display the burn-in status for a switch.
Usage Guidelines None
Examples To display the diagnostics burn-in status:
switch# show diag burninstatus
DiagID State Status Run Cmd TotCmds PID Script SlotID
1 COMPLETE_TESTED PASS 1 8 8 23163 verify L1
2 COMPLETE_TESTED PASS 1 8 8 23311 verify L2
6 COMPLETE_TESTED PASS 1 5 5 23465 verify S2
7 COMPLETE_TESTED PASS 1 5 5 23618 verify S3
8 COMPLETE_TESTED PASS 1 5 5 23787 verify S4
9 COMPLETE_TESTED PASS 1 5 5 23976 verify S5
10 COMPLETE_TESTED PASS 1 5 5 24156 verify S6
12 COMPLETE_TESTED PASS 1 8 8 24388 verify L6
14 COMPLETE_TESTED PASS 1 8 8 24692 verify L8
rbridgeId 1
See Also diag burninerrclear, diag clearerror, show diag burninerrshow