show edge-loop-detection rbridge-id
2
show edge-loop-detection rbridge-id
Displays ELD status information for a specific RBridge.
Synopsis show edge-loop-detection rbridge-id {rbridge-id | all}
Operands rbridge-id Specifies an RBridge ID for the switch.
all Specifies all RBridge IDs in the VCS cluster.
Defaults None
Command Modes Privileged EXEC mode
Description Use this command to view the configuration and status of ELD on a specific RBridge, including the
ports that ELD has disabled. For each interface on which ELD is enabled, this command shows the
enabled VLANs, the ELD port priority, the up/down status of the interface, and time to the next
automatic port re-enable.
Usage Guidelines This functionality detects Layer 2 loops only.
If rbridge-id rbridge-id is specified, ELD data for the node with that particular rbridge-id is
displayed.
If rbridge-id all is specified, ELD data from all the nodes in the cluster is displayed.
Examples To view the ELD status:
switch# show edge-loop-detection rbridge-id 7
Number of edge-loop-detection instances enabled: 1
Interface: 7/0/5
------------------------
Enabled on VLANs: 100
Priority: 128
Interface status: UP
Auto enable in: Never
See Also clear edge-loop-detection, edge-loop-detection vlan, edge-loop-detection port-priority,
shutdown-time