TurboIron(config)#snmp-server enable traps holddown-time 30
The command in this example changes the holddown time for SNMP traps to 30 seconds. The
device waits 30 seconds to allow convergence in STP and OSPF before sending traps to the SNMP
trap receiver.
Syntax: [no] snmp-server enable traps holddown-time <secs>
The <secs> parameter specifies the number of seconds and can be from 1 – 600 (ten minutes).
The default is 60 seconds.
Disabling SNMP traps
TurboIron X Series devices come with SNMP trap generation enabled by default for all traps. You
can selectively disable one or more of the following traps.
NOTE
By default, all SNMP traps are enabled at system startup.
Layer 2 traps
The following traps are generated on devices running Layer 2 software:
SNMP authentication keys
Power supply failure
Fan failure
Cold start
Link up
Link down
Bridge new root
Bridge topology change
Locked address violation
Layer 3 traps
The following traps are generated on devices running Layer 3 software:
SNMP authentication key
Power supply failure
Fan failure
Cold start
Link up
Link down
Bridge new root
Bridge topology change
Locked address violation
BGP4
OSPF
VRRP