User Manual

162 Unified IP MIB Reference
53-1003106-01
Trap receiver table
5
Trap receiver table
The trap receiver table allows you to configure trap receivers on IPv4 devices.
NOTE
To delete a trap receiver, the agent needs the following varbinds in the setRequest PDU:
snAgTrpRcvrIpAddr, snAgTrpRcvrCommunityOrSecurityName, and snAgTrpRcvrStatus. The
snAgTrpRcvrStatus object must be set to delete(3).
snAgentBrd2MainBrdId
(continued)
LX_SX_FIBER=4
LHB_FIBER=5
Octet 10 to Octet 13 – Size of DRAM in Kilobytes.
Octet 14 to Octet 17 – Size of boot flash in Kilobytes.
Octet 18 to Octet 21 – Size of code flash in Kilobytes.
Octet 22 to Octet 27 – Serial number.
Octet 28 – Chassis backplane type:
chassis4000 – 0x00
chassis8000 – 0x02
chassis15000 – 0x01
chassisFISX – 0x04
Turbo8 – 0x07 (stack2)
FastIron2 – 0x06 (stack1)
snAgentBrd2MainPortTot
al
brcdIp.1.1.2.2.2.1.5
Syntax: Integer
Read-only The total number of ports for the main board.
snAgentBrd2ModuleStat
us
brcdIp.1.1.2.2.2.1.6
Syntax: Integer
Read-only Shows the status of the module. The following are the status of the
module:
moduleEmpty(0) – The slot of the chassis is empty.
moduleGoingDown(2) – The module is going down.
moduleRejected(3) – The module is being rejected due to wrong
configuration.
moduleBad(4) – The module hardware is bad.
moduleConfigured(8) – The module is configured (stacking).
moduleComingUp(9) – The module is in power-up cycle.
moduleRunning(10) – The module is running.
moduleBlocked(11) – The module is blocked for full height card.
By default, this mode is set to notActivated(0).
snAgentBrd2RedundantS
tatus
brcdIp.1.1.2.2.2.1.7
Syntax: Integer
Read-only The status of a redundant module. Non-management modules always
return other(1). Management modules return the other states:
other(1)
active(2)
standby(3)
crashed(4)
comingUp(5)
Name, OID, and syntax Access Description