Unified IP MIB Reference 297
53-1003106-01
Chapter
22
NetFlow and sFlow MIB
In this chapter
•NetFlow Export. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 297
•sFlow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300
NetFlow Export
The following objects provide configuration information on the NetFlow Export feature.
NetFlow Export collects information about the traffic that devices receive, then forwards and
exports that information to a third-party collector. Third-party applications can then use the
information to create reports, bill customers for network usage, and so on.
NOTE
The following snNetFlowGlb, snNetFlowCollectorTable, snNetFlowAggregationTable, and
snNetFlowIfTable are not supported on the Brocade NetIron and Brocade FastIron series devices.
Global NetFlow objects
Name, OID, and syntax Access Description
snNetFlowGblEnable
brcdIp.1.1.3.18.1.1
Syntax: Integer
Read-write Determines if NetFlow Export is enabled:
• disabled(0)
• enabled(1)
Default: disabled(0)
snNetFlowGblVersion
brcdIp.1.1.3.18.1.2
Syntax: Integer
Read-write Shows the NetFlow Export version.
Default: Version 5
snNetFlowGblProtocolDis
able
brcdIp.1.1.3.18.1.3
Syntax: Integer32
Read-write Indicates if TCP or UDP are disabled:
• Bit 0 – Disables the export of all protocols except UDP and TCP.
• Bit 1 – Disables the export of TCP.
• Bit 2 – Disables the export of UDP.
Default: Bit 0
snNetFlowGblActiveTime
out
brcdIp.1.1.3.18.1.4
Syntax: Integer32
Read-write Specifies the maximum number of minutes that an active flow can be in
the NetFlow Export cache.
Valid values: 1 – 60 minutes
Default: 60 minutes
snNetFlowGblInactiveTim
eout
brcdIp.1.1.3.18.1.5
Syntax: Integer32
Read-write Specifies the maximum number of seconds that an inactive flow can be
in the NetFlow Export cache.
Valid values: 1 – 60 seconds
Default: 60 seconds