5. Open the ejectors on the new SFM by rotating them toward the center of the module face. Orient the switch
fabric module so that the ejectors are toward you.
6. Align the module pan with the guides in the slot. The first SFM ashould be installed in slot S3.
7. Push the SFM firmly into the slot.
8. Close the ejectors by rotating them away from the center of the SFM. The levering action of the ejectors seats
the module in the slot.
9. Tighten the captive screws using the Phillips screwdriver.
10. Pull out the power enable pin and move the slider all the way down.
11. Screw in the power enable pin.
12. Tighten the screws on the slider.
FIGURE 6 Inserting a switch fabric module
Inserting a line card
For this procedure, refer to “ESD precautions” and Figure 7.