Programmer's Guide (Supporting ADX v03.1.00) Manual

Brocade Virtual ADX XML API Programmer’s Guide 255
53-1003248-01
Data structures
4
duplex portDuplexTypeEnum Optional Valid only when the
interface type is
ETHERNET.
This parameter is
mandatory when the
“isAutoNegotiation”
parameter is either not
present or set to
“FALSE”.
This parameter is
mandatory when the
“speed” parameter is
present.
When the “speed
parameter is
“1_GIGABIT”, this
parameter value is not
considered.
When present as part
of the request
message, the valid
values are:
•HALF
•FULL
The duplex port.
gigabitMode portSpeedGigabitModeEnum Optional Valid only when the
interface type is
ETHERNET.
This parameter is
mandatory and
considered only when
the value of parameter
“speed” is
“1_GIGABIT”.
When present as part
of the request
message, the valid
values are:
•MASTER
•SLAVE
The gigabit mode.
enableFlowControl boolean Optional Valid only when the
interface type is
ETHERNET.
The default value is
"FALSE".
Enables or disables
802.3x flow control
on full duplex port.
enableIpv6 boolean Optional The default value is
"FALSE".
This parameter is valid
in Router mode, and
invalid when the
interface type is
MANAGEMENT.
Enables or disables
IPv6 on the
interface.
TABLE 637 Attributes (Continued)
Name Type Presence Rules Description