Programmer's Guide (Supporting ADX v03.1.00) Manual

608 Brocade Virtual ADX XML API Programmer’s Guide
53-1003248-01
Methods
6
Parameters
Table 145 contains the parameters required for the method.
Return values
Not applicable.
Error messages
List of Error Messages
Syn-Proxy
Syn-Proxy allows TCP connections to be terminated on the ServerIron ADX device. When Syn-Proxy
is enabled, the ServerIron ADX switch completes the three-way handshake with a connecting client.
Only when the three-way handshake is successfully completed does the ServerIron ADX switch
establish a connection with the destination server and forward packets from the client to the
server.
setSynProxyGlobalConfig
Description
Sets the global Syn-Proxy configuration.
Parameters
Table 146 contains the parameters required for the method.
Return values
Not applicable.
Error messages
List of Error Messages
updateSynProxyGlobalConfig
Description
Updates the global Syn-Proxy configuration.
TABLE 145 Parameters
Name Type Presence Rules Description
version ipVersionEnum Mandatory Identifies the IP (IPv4 or IPv6) address of the device.
firewall Firewall [ ] Mandatory Identifies the firewall data structure.
TABLE 146 Parameters
Name Type Presence Rules Description
config SynProxyGlobalConfig Mandatory Global configuration for Syn-Proxy.