Programmer's Guide (Supporting ADX v03.1.00) Manual

Brocade Virtual ADX XML API Programmer’s Guide 791
53-1003248-01
List of Error Messages
A
SLB_STATUS_CODE_MIN_OUT_OF_RANGE The specified status code minimum value %d is out of
range. Please specify a valid value in the range of %d to
%d.
SLB_STATUS_CODE_MISMATCH The specified status code pair %d-%d is invalid. The
status code minimum value should not be greater than
the status code maximum value.
SLB_STATUS_CODE_MISSING_MAX The maximum status code value is missing. Please
specify both the minimum and maximum status code
pair(s).
SLB_STATUSCODE_IMPROPER The specified status code range is invalid. Please specify
a valid value range of 100 to 999.
SLB_STICKY_ACL_ID_INVALID The sticky ACL ID value is out of range. Please specify a
valid Interval in the range of %d to %d.
SLB_STICKY_CONFIG_ERROR The client subnet sticky, and sticky, or persist hash cannot
be defined for the same port. Please configure the sticky
or client subnet sticky.
SLB_SUPER_SOURCEIP_INVALID The specified IP address is a super source IP, and cannot
be configured as source IP under the serverThe IP
address %I is a super source IP, specify an appropriate IP
address.
SLB_SVC_CAM_ERR Internal CAM error. Please retry the operation.
SLB_SVC_CNTR_SYNC_ERR Service sync error
SLB_SVC_DENY_VIP_PROTECTION Cannot configure SIP, RTSP, MMS, TFTP or FTP ports as
VIP protection is already configured. VIP protection must
be disabled before configuring SIP, RTSP, MMS, TFTP or
FTP ports.
SLB_SVC_DOESNT_EXIST The specified server does not exist. Please specify a
different server name or create a new server.
SLB_SVC_EXISTS The server specified in the request already exists. Please
specify a different server name.
SLB_SVC_INVALID_PORT The specified port is invalid. Please specify a valid port for
the server.
SLB_SVC_INVALID_SVR The server specified in the request is invalid. Please
specify the correct server.
SLB_SVC_NO_DEF_PORT The specified server port is not defined. Please create the
port first and try again.
SLB_SVC_NO_PORT The server does not have any ports. Please create ports
on the server.
SLB_SVC_NOT_COMPAT Service is not compatible
SLB_SVC_OUT_OF_CNTRS No more counters are available for this service
SLB_SVC_OUT_OF_PORTS No additional ports can be added to the server. The
maximum port limit for the server has been reached.
SLB_SVR_AWAITING_SHUTDOWN Server is shutting down. The requested server is in the
process of shutting down. Please retry after some time.
SLB_SVR_CAM_ERR A CAM operation returned an error
TABLE 109 List of error messages
Error String Message