Programmer's Guide (Supporting ADX v03.1.00) Manual

88 Brocade Virtual ADX XML API Programmer’s Guide
53-1003248-01
Data structures
3
BannerMessage
This structure is a high-level description for configuring the banner messages on Brocade Virtual
ADX.
boardID
This structure is the high-level description of the chassis board.
BpID
This structure is the high-level description of BP number.
TABLE 214 Attributes
Parameters Type Presence Rules Description
messageOftheDay string Mandatory Maximum 2548 characters
is allowed. The string can be
from 1 – 2548 characters in
length.
This parameter specifies an ASCII
string message to be displayed on a
User’s terminal whenever a Telnet
CLI session is established.
connectionMessage string Optional Maximum 2548 characters
is allowed. The string can be
from 1 – 2548 characters in
length.
This parameter specifies an ASCII
string message to be displayed on
the Console when a user
establishes a Telnet session. This
message indicates where the user is
connecting from and displays a
configurable text message.
execMessage string Optional Maximum 2548 characters
is allowed. The string can be
from 1 – 2548 characters in
length.
This parameter specifies an ASCII
string message to be displayed
when a user enters the Privileged
EXEC CLI level.
TABLE 215 Attributes
Name Type Required Rules Description
bootPromMac string Yes The MAC address of the boot PROM.
model string Yes The chassis model.
serialNum string Yes The serial number of the chassis.
TABLE 216 Attributes
Name Type Required Rules Description
asmSlotNumber unsignedInt The chassis slot containing the module.
bpNumber unsignedInt The BP (numbered from 1 – 8 maximum).