Advanced performance monitoring graphs
This section describes how to create the advanced performance monitor graphs listed in Predefined
performance graphs on page 126. Because the procedure for creating these graphs differs depending
on the type of graph, each type is described separately in the sections that follow.
The advanced monitoring graphs are not supported for GbE ports.
NOTE
You must have an Advanced Performance Monitoring license installed to use the Advance Performance
Monitor features. If user-defined Admin Domains are configured, Advanced Performance Monitoring
works only in AD255.
Creating SID/DID Performance graphs
The SID/DID Performance graph displays the traffic between a SID/DID pair on the switch being
managed.
To create a SID/DID Performance graph, perform the following steps.
1. Open the Performance Monitoring window.
2. Select Performance Graphs > Advanced Monitoring > SID/DID Performance. The SID/DID
Performance Setup dialog box displays.
To see the end-to-end (EE) monitors that are currently set up on a particular port, proceed to step
3.
To specify the port, Source ID and Domain ID, skip to step 4.
NOTE
Only the FC ports of the launched switch display in the tree. The All Devices tab lists all the devices
in the fabric and lets you select the source and destination. Slot and port information of other
switches is not displayed in the tree.
3. Click a port from the Slot/Port or Sid/Did Selection List.
a) Drag the selected port into the Enter/drag slot, port number field.
b) Click Retrieve preset EE monitors. The current end-to-end monitors for that port are
displayed in the "Current EE monitors set for selected port" table.
c) Optional: To display a performance graph for the current EE monitors set for the selected
port, click a SID/DID pair in the table. You can select multiple Source ID and Destination
IDs. Click Select. If you selected multiple SID/DID monitors, click OK in the confirmation
dialog box that displays. Skip to step 6. If you do not want to display a performance graph
for the current EE monitors set for the selected port, continue with step 4.
4. Select a source ID from the Port or Sid/Did Selection List, and click Add Sid.
You can also enter a source ID in the Enter/drag SID number field.
5. Select a destination ID from the Port or Sid/Did Selection List, and click Add Did.
You can also enter a destination ID in the Enter/drag DID number field.
6. Click OK.
If you selected multiple EE monitors, SIDs, or PIDs, a confirmation dialog box displays, reminding
you that one graph is opened for each selection.
Advanced performance monitoring graphs