Administrators Guide (Supporting Fabric OS v7.3.0) Manual

To configure the IP and subnet mask information, perform the following steps.
1. Select the Network tab.
2. In the appropriate IP address section, enter the IP address you want to use for the IP interface.
Use the IPv4 Address section or the IPv6 Address section to specify IP addresses.
3. In the IPv4 Address section:
In the Ethernet IP field, enter the Ethernet IP address.
In the IPFC Net IP field, enter the IPFC net IP address.
In the Ethernet Mask field, enter the Ethernet mask address.
In the IPFC Net Mask field, enter the IPFC net mask address.
In the Gateway IP field, enter the gateway IP address.
4. In the IPv6 Address section, in the Ethernet IPv6 field, enter the Ethernet IP address.
5. You can also enable automatic configuration of IPv6 addresses by selecting Enable IPv6 Auto
Configuration.
The automatically generated IPv6 addresses are displayed under Auto Configured IPv6
Addresses. Eight auto-configured addresses are created per switch, and up to 24 for a DCX, or
DCX-4S chassis (eight per chassis, and eight per each installed CP).
Configuring Netstat Auto Refresh
The Netstat Performance window displays the details about Ethernet management port statistics such
as the Interface, MTU, Met, RX-OK, RX-ERR, RX-DRP, RX-OVR, TX-OK, TX-ERR, TX-DRP, TX-
OVR, and Flag.
To configure Auto Refresh, perform the following steps.
1. Open the Switch Administration window as described in Opening the Switch Administration
window on page 52.
2. Select the Network tab.
3. Click Netstat Performance.
4. Select the Auto Refresh check box to automatically refresh the port details.
Clear the check box to disable auto refresh.
5. When enabled, enter the interval time in seconds in the Auto-Refresh Interval field.
The port details are automatically refreshed, based on the configured time interval. The minimum
value is 15 seconds.
Configuring a syslog IP address
The syslog IP address represents the IP address of the server that is running the syslog process. The
syslog daemon reads and forwards system messages to the appropriate log files or users, depending
on the system configuration. When one or more IP addresses are configured, the switch forwards all
error log entries to the syslog on the specified servers. Up to six servers are supported. Refer to the
Fabric OS Administrator's Guide for more information on configuring the syslog daemon.
To configure a syslog IP address, perform the following steps.
Configuring Netstat Auto Refresh
54 Web Tools Administrator's Guide
53-1003169-01