GENERAL OPERATING INFORMATION
Rated Capacity
3,500 gal. for Aesthetic Chlorine / 243 gal. for VOC’s
Min-Max operating pressure:
40psi-120psi (275Kpa-827Kpa)
Min-Max feed water temperature:
41°F – 95°F (5°C – 35°C)
Rated Service Flow
0.07 gallons per minute (gpm)
Faucet Flow Rate
0.26–0.37 gpm (at incoming water pressure of 20–100psi)
Daily Water Production Rate
56.9 gallons per day
Product Eciency Rating
30.6%
• Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before
or after the system.
• Refer to the owners manual for specic installation instructions, manufacturer’s limited warranty, user responsibility,
and parts and service availability.
• The inuent water to the system shall include the following characteristics:
• No organic solvents
• Chlorine: < 2 mg/L
• pH: 7 - 8
• Temperature: 41 ~ 95 ºF (5 ~ 35 ºC)
• Systems certied for cyst reduction may be used on disinfected waters that may contain lterable cysts.
• Iron: < 2 mg/L
• Turbidity: < 1 NTU
• Hardness: < 1 000 mg/L
Substance
Inuent Challenge
Concentration
(mg/L unless specied)
Maximum Allowable Product
Water Concentration
(mg/L unless specied)
Percent Reduction
(%)
Arsenic (Pentavalent) 0.05 +/- 10% 0.01 98.9
Barium 10.0 +/- 10% 2 98.2
Radium 226/228 25 pCi/L 5 pCi/L 80
Cadmium 0.03 +/- 10% 0.005 98.2
Chromium (Hexavalent) 0.3 +/- 10% 0.1 97.3
Chromium (Trivalent) 0.3 +/- 10% 0.1 97.8
Copper 3.0 +/- 10% 1.3 98.7
Lead 0.15 +/- 10% 0.01 98.2
Selenium 0.10 +/- 10% 0.05 97.3
Fluoride 8.0 +/- 10% 1.5 83.8
TDS 750 +/- 40 187 92.5
Aesthetic Chlorine 2.0 +/- 10 % >/= 50% Reduction 98.4
VOCs 0.300 +/- 10% >/= 95% Reduction 99.8
Cyst 12NTU >99.95% 99.96
While testing was performed under laboratory conditions, actual performance may vary.
The RC100 is tested and certied to NSF/ANSI 42, 53 and 58 for the reduction of Aesthetic Chlorine, Taste
and Odor, Cyst, VOCs, Fluoride, Pentavalent Arsenic, Barium, Radium 226/228, Cadmium, Hexavalent
Chromium, Trivalent Chromium, Lead, Copper, Selenium and TDS as veried and substantiated by test
data. The RC100 conforms to NSF/ANSI 372 for low lead compliance.
This system has been tested according to NSF/ANSI 42, 53 and 58 for the reduction of the substances
listed below. The concentration of the indicated substances in water entering the system was reduced
to a concentration less than or equal to the permissible for water leaving the system, as specied in NSF/
ANSI 42, 53 and 58.
CIRCLE FILTRATION SYSTEM PERFORMANCE DATA SHEET
Model: RC100
22