8.2.3 Message set
The SECSII-message-set used by the HERMOS SECS-1 reader consist of 6
different stream types.
Stream 1 : (Equipment status)
- S1F1 and S1F2 Are you there request
- S1F15 and S1F16 Request offline
- S1F17 and S1F18 Request online
Stream 2 : (Equipment control)
- S2F13 and S2F14 equipment constant request
- S2F15 and S2F16 new equipment constant request
- S2F19 and S2F20 reset send
Stream 3 : (Material status)
- S3F5 and S3F6 cassette found send
- S3F7 and S3F8 cassette lost send
- S3F11 and S3F12 read MID at I/O port
- S3F13 and S3F14 return read MID
- S3F65 and S3F66 write MID at I/O port
- S3F67 and S3F68 return write success
Stream 5 : (Exception handling)
- S5F1 and S5F2 alarm report send
Stream 9 : (System errors)
- S9F1 unrecognized device ID
- S9F3 unrecognized stream type
- S9F5 unrecognized function type
- S9F7 illegal data
- S9F9 transaction timer timeout
In attention of the SEMI E99 Carrier ID Read/Writer functional standard for SECS-1
and SECS-2 protocol, the HERMOS SECS-1 reader supports the defined Stream
18 messages.