User's Manual

RS232-Transponder Reader
(SECS1-Protocol), Release 0.3 Draft Page 83 of 91
2000-09-29
ID: ID000093
10 SECS-1 MESSAGE EXAMPLES
All examples are produced with the default gateway-ID 255 (decimal) or 0x00FF
(hexadecimal) !
1. S1F1 Message from the reader to the host
Gateway to Host: S1F1
16:54:47 Incoming: ENQ ( 05 )
16:54:47 Outgoing: EOT ( 04 )
16:54:47 Incoming: Length Byte ( 0A )
16:54:47 Incoming: Header ( 81 FF 81 01 80 01 00 00 00 01 )
16:54:47 Incoming: Checksum ( 02 84 )
16:54:47 Outgoing: ACK ( 06 )
Host to Gateway: S1F2
16:54:48 Outgoing: ENQ ( 05 )
16:54:48 Incoming: EOT ( 04 )
16:54:48 Outgoing: Length Byte ( 10 )
16:54:48 Outgoing: Header ( 01 FF 01 02 80 01 00 00 00 01 )
16:54:48 Outgoing: Data ( 01 02 41 00 41 00 )
16:54:48 Outgoing: Checksum ( 09 03 )
16:54:48 Incoming: ACK ( 06 )
2. S1F1 Message from the host to the reader
Host to Reader: S1F1
16:59:20 Outgoing: ENQ ( 05 )
16:59:20 Incoming: EOT ( 04 )
16:59:20 Outgoing: Length Byte ( 0A )
16:59:20 Outgoing: Header ( 01 FF 81 01 80 01 00 00 00 01 )
16:59:20 Outgoing: Checksum ( 03 03 )
16:59:20 Incoming: ACK ( 06 )
Reader to Host: S1F2
16:59:20 Incoming: ENQ ( 05 )
16:59:20 Outgoing: EOT ( 04 )
16:59:20 Incoming: Length Byte ( 1C )
16:59:20 Incoming: Header ( 81 FF 01 02 80 01 00 00 00 01 )
16:59:20 Incoming: Data ( 01 02 41 06 67 61 74 65 53 32 41 06 56 )
16:59:20 Incoming: Data ( 31 2E 31 2E 30 )
16:59:20 Incoming: Checksum ( 06 00 )
16:59:20 Outgoing: ACK ( 06 )