Product Manual - RFID Reader UF70 Certum 114
Chapter 7
Operation
UPD – Define
default parameter
set
For the typical reader parameters (parameter number 100 to max. 240), up to 8
parameter sets can be created and selected. The default parameter set is the one
that is loaded when starting the reader and automatically becomes the active
parameter set. The parameter set number (0 to 7) of the default parameter set
can be defined with the UPD command. If the UPD command has a parameter set
number greater than 7, the currently active parameter set is used as the default
parameter set.
Example:
set new default parameter
>> UPD007
<< upd000
Default parameter set number successfully set
>> UGD0
<< ugd007
Default parameter set number 07
....
Poweroff reset
....
<< n0
>> UGD0
<< ugd007
Default parameter set number 07
Example: Set default parameter set as the active parameter set
>> UGD0
<< ugd007
Default parameter set number 07
>> UGK0
<< ugk007
Active parameter set number 07
>> UPK000
<< upk000
Reader host
CMD Reader ID Parameter set no.
UPD 1 byte 2 bytes
Host reader
CMD Reader ID Result
upd 1 byte 2 bytes