User's Manual

Table Of Contents
Product Manual - RFID Reader UF70 Certum 125
Chapter 7
Operation
Sensor triggered
automatic reading
The response can be set for each of the four inputs by parameters (26 to 29)
Watch port. An automatic reading can also be automatically initiated on the
respective antenna, in addition to sensor message "B". An EPC bulk reading "urb"
is performed over a set time period as an automatic reading. The time frame can
be set via parameter (33 and 34) Auto read Bulk time.
Example:
<< B011 Sensor status at sensor 1 is "On"
<< URB0000001 Result 0x00 and extension 0x01
01060B0C090A0708050603041122
01060B0C090A0708050603040102
<< B010 Sensor status at sensor 1 is "Off"
<< B021 Sensor status at sensor 1 is "On"
<< URB0000A Result 0x0A no transponder is detected
<< B020 Sensor status at sensor 1 is "Off"