Chapter 7
Operation
Parameter 34
(0x22)
Low-byte Auto Read Bulk Time
An EPC bulk reading is completed in the sensor-triggered automatic reading. The
duration of the bulk reading is specified in milliseconds. The low byte of the 2 byte
time value is defined here.
0x1234 Lowbyte 0x34
Default: 0x00 (0x0100: 256 ms)
Parameter 39
(0x27)
Adjust I/O numbering
Antennas and I/Os have the same numbering. This applies for inputs and outputs
Sensor 1 therefore becomes sensor 4 and vice versa.
0: Do not provide an adjustment (compatibility to previous versions)
1: Adjust I/Os
Default: 0x01
Parameter 40
(0x28)
Polling port
The antenna port is defined with this parameter, on which a polling EPC scan
(asynchronous EPC scanning) is performed. Polling is started after a reset
according to the value of the parameter polling port.
Value range:
0x00: No polling
0x01: Polling EPC on antenna 1
0x02: Polling EPC on antenna 2
0x04: Polling EPC on antenna 3
0x08: Polling EPC on antenna 4
0x0F: Polling EPC on all 4 antennas
Default: 0x00 (no polling)
ATTENTION
If polling is stopped by the "UAE" command, the parameter polling port is not
affected. Polling is restarted according to the parameter at the next reset.
Resetting the parameter to value 0x00 stops polling!